Air Shower Clean Room

Cleanroom Service: Design, Build and Install. Clean Room Equipment and Supplies: Modular Clean Room, Air Shower

The Working Principle And Workflow Of The Air Shower

First, the working principle of the air shower. Benefits of Air Showers And How Air Showers Are Used


After the air is filtered by the primary air filter, it is pressed into the static pressure box of the air shower by the high pressure fan of the air shower, and the clean airflow filtered by the high efficiency air filter is sprayed to the person from all directions by the rotatable nozzle, so as to effectively and quickly remove the dust particles from the person. The air with dust particles and then through the primary air filter and high efficiency air filter again into the clean air cycle to the air shower.Cleanroom Air Showers: Everything You Need To Know


The Working Principle And Workflow Of The Air Shower


Second, the workflow of the air shower


1, Enter the door (from outside the air shower and then inside the air shower)-Enter the clean room from the non-clean room.

Open the outer door ---- Electric lock on the inner door ------ Enter the air shower ------- Close the outer door (voice prompts to stand in the induction area) Inner and outer door self-locking ------ Infrared induction blowing shower begins (voice prompts blowing shower process) --------- Blowing shower completed (voice prompts) ----- Enter the clean room (inner door automatically unlocked)


2, open the outer door, the inner door on the electronic interlock, air shower lighting, work indicator light, people into the air shower, close the outer door, voice prompts." Hello, please stand to the induction area". By the external intelligent system began to detect whether there is someone in the air shower, such as the detection of someone, the system that turns into the wind shower program.Air Shower Cheap Price Food Industry Class 100 Clean Room



3, air shower inside and outside the door interlock, the fan began to start the wind shower, wind shower delay began to countdown I5S (set value). Voice prompt." Is working, please turn the body 360 degrees", the end of the wind shower, the beginning of the delay, the end of the delay, the wind shower room inside and outside the door automatically unlocked, voice prompts." Blowing shower is over, please exit from the back door", people come out from the inner door to enter the clean room, the inner door is closed, the system returns to the initial state, waiting for the next use. (Note: If you want to return to the non-clean room after the end of the delay, please press the "emergency stop" key, the inner and outer doors unlock, you can return to the non-clean room.) (Note: To return to the non-clean room after the delay is over, please press the "emergency stop" key and the inner and outer doors will be unlocked.


4, If the system detects no one in the air shower within 10 seconds, the system returns to standby (infrared automatic detection system). In the standby state, such as the system detects the human body, the air shower begins to wind shower, but the standby state for more than 10 seconds, the system returns to the initial state.


5, such as someone in the air shower, but not in the system induction area, the system does not respond, the system detects someone, the system turns into the wind shower process.


6, such as the system is working, when someone touches the key switch, voice prompts." Is working, please do not touch the switch".


7, in the air shower after the completion of the entire blowing process, air shower inside and outside the door automatically unlocked, at this time can enter or leave the air shower; such as air shower area someone in 5 seconds did not leave the air shower, the system automatically returns to the initial state.


8, Go out (from inside to outside) - from the clean room to the non-clean room.

Open the inner door -------- The outer door is electrically self-locking ------- Enter the air shower --------- Close the inner door -------- Unlock the inner and outer doors ---- Enter the non-clean room ---------- Return to the clean room.


9, open the inner door, the outer door on the electronic interlock, air shower lighting, work indicator light, people into the air shower, close the inner door, the inner and outer doors unlock, the system began to detect whether there is someone in the air shower.


10, If someone is detected: you can choose the inner door to go out: open the inner door, the outer door on the electric self-locking, and then close the inner door, the system returns to the initial state or choose the outer door to go out, open the outer door, the inner door on the electric self-locking, then close the outer door. The system returns to the initial state.What are the requirements for the car painting air shower room


11, If no one is found. At this time, someone opens the outer door, the system turns to the door opening process.


12, in the process of going out, such as the system detects someone entering the air shower, the outer door unlocked, the person inside does not leave the air shower within 5 seconds, the system automatically returns to the initial state.



More of your interest


Industrial Clean Rooms GMP Workshops
What Is The Role Of Air Shower Room
Advantages Of High-Performance Clean Room Doors
Air Shower Design And Application Guidelines
Determinants Of Air Shower Performance
Where The Air Shower Should Be Installed
How Much Does An Air Shower Cost In General
What Are The Air Shower Vulnerable Parts
Suggestions For The Safe Use Of Air Shower
Air Shower Channel Use Requirements Note


cache
Processed in 0.005240 Second.